Back to Tools

Precision Study Calculator

Free intra-day and inter-day precision study tool for medical laboratories. Enter your replicate results and get the mean, SD and CV% in a printable report.

Select Precision Study

Choose the type of precision validation to perform.

About the precision study

A precision study shows how closely repeated measurements of the same sample agree with each other. ISO 15189:2022 expects a laboratory to verify the performance claimed by the manufacturer before a new method or analyser is used for patients, and precision is one of the first things an NABL assessor asks to see.

This tool covers both intra-day (within-run) and inter-day (between-day) designs. You enter the lab and equipment details, the study dates and the replicate values for each control or sample level. It then calculates the mean, standard deviation (SD) and coefficient of variation (CV%) for every level, and builds a PDF report you can file with your validation records.

Values that cannot be calculated, such as the SD of a single data point, are shown as a dash rather than a zero, so an incomplete study never prints as a passing result. Your entries are stored in your own browser only.

How to use this tool

  1. Choose the study type. Intra-day measures the same sample repeatedly in one run; inter-day spreads the replicates over three days, five a day, to capture day-to-day change.
  2. Enter the lab name, department, equipment and study start date. For an inter-day study the tool fills in the date of each replicate from the start date.
  3. Name the parameters you are testing, up to ten, and enter the replicate results. You can paste a block of results straight from a spreadsheet instead of typing them one by one.
  4. Check the mean, SD and CV% calculated for each parameter, and compare the CV% with the limit your laboratory or the manufacturer has set for that test.
  5. Download the PDF report, sign it and file it with your method verification records.

Frequently asked questions

What is the difference between repeatability and intermediate precision?

Repeatability (within-run precision) is the agreement between results measured in quick succession under the same conditions. Intermediate precision adds the changes a laboratory sees in normal work, such as different days, calibrations and operators. The intra-day design measures the first; the inter-day design gives a view of the second.

Why is CV% used rather than SD alone?

The SD is in the units of the test, so it naturally grows with concentration. The coefficient of variation divides the SD by the mean, which lets you compare precision across levels and against limits that are stated as a percentage.

Which samples should I use?

Use material that behaves like patient samples and is stable for the length of the study, often the laboratory's own control materials. Testing at more than one level, such as normal and abnormal, shows whether precision holds across the range you report.

Can I use the report in an NABL assessment?

The report records the design, raw data, statistics and a signature line, which is the evidence assessors usually ask for. Your laboratory still decides the acceptance limits and signs off the result under its own procedures.

How long does an inter-day study take?

The tool's inter-day design runs over three days with five replicates a day. Plan the samples and control material so the same lot lasts the whole study.

What if a single result looks wrong?

Look for a reason before excluding it: a short sample, a clot, a bubble or a sample mix-up. If there is a clear cause, record it and repeat that measurement. Removing results without a documented reason makes precision look better than it is, and assessors will ask about it.

Is my data sent anywhere?

No. The calculations run in your browser, and your entries are saved only in that browser so you can come back to them later.

Read the full guide: Precision study as per ISO 15189:2022 and CLSI guidelines. More free calculators are on the Tools page. Preparing your laboratory for accreditation? See our NABL consultancy.

Contact on Whatsapp